Products
Mars Air Systems
United States
    Standard 2 (STD2)

    9235

    91

    137

    Contact supplier
    Favorites Like

    Description

    Catalogues

    Videos

    The Standard series, a commercial and industrial hybrid, is our most popular energy-saving series. It features a ½ horsepower power motor(s) that is louder and stronger than the LoPro but is ideal for a multitude of customer-facing and industrial applications.  It is also available in ETL Sanitation Certified versions and is suitable for heights up to 10 ft (ETL Sanitation rated for 7 ft heights.)  The standard color on all models is Obsidian Black and heated options are available.
    To view our ETL Sanitation certified series, click here:

    OVERVIEW

    18-month warranty
    5-year warranty
    Certifications
    Corrosion Resistant Powder Coated Finish
    Durable Metal Construction
    Durable metal design
    Easy To Install
    Environmental Protection: 10’
    Flying-insects Protection: 8’
    Freight included
    Low Maintenance
    Made in USA
    Motor fan assembly
    Sleek metal design
    Standard color: Obsidian Black (matte)
    ½ hp direct-drive motor

    MODELS


    ACCESSORIES

    DOOR SWITCHES
               
    Automatic on/off control of air curtain as door is opened and closed         
     
    Line Voltage  
     
    - 99-014  Door Limit Switch Combination roller and plunger · 20 amps, 250v, or 1 hp max.
     
    24-Volt Control         
     
    - 99-018  Commercial Magnetic Reed Switch Only - Plastic · Surface-mounted · NOTE: Used with control packages for double doors    
    - 99-124  Industrial Floor-Mounted Magnetic Reed Switch Only - Floor-mounted · NOTE: Control panel required         
    - 99-125  Industrial Surface-Mounted Magnetic Reed Switch Only - Surface-mounted · NOTE: Control panel required         
     
    CONTROL PACKAGES           
     
    Combination packages of door switches, controllers, time delays, and thermostats          
     
    Line Voltage  
     
    - 99-063  Analog Thermostat - Remote-mounted       
    - 99-064  Analog Thermostat DPST - Double pole, single throw · Acts as heat on demand · Remote-mounted           
     
    24-Volt Control         
     
    - J0021   Commercial Magnetic Reed Switch with Controller and Adjustable Time Delay · 115v, 6 sec. – 20 min. · Plastic · Surface-mounted       
    - J0022   Commercial Magnetic Reed Switch with Adjustable Time Delay ·208-230v 1?, 6 sec. – 20 min. · Plastic · Surface-mounted      
    - J0023   Commercial Magnetic Reed Switch with Controller · 115v, Plastic · Surface-mounted      
    - J0024   Commercial Magnetic Reed Switch with Controller · 208-230v 1?, Plastic · Surface-mounted     
    - J0028   Door Limit Switch with Controller and Adjustable Time Delay ·115v, 6 sec. – 20 min. · Surface-mounted         
    - J0029   Door Limit switch with Controller and Adjustable Time Delay ·208-230v 1Φ - 6 sec. – 20 min. · Surface-mounted       
    - J0034   Door Limit Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required           
    - J0036   Industrial Magnetic Reed Switch with Controller · 115v, Surface-mounted
    - J0037   Industrial Magnetic Reed Switch with Controller · 208-230v 1Φ - Surface-mounted          
    - J0038   Industrial Magnetic Reed Switch with Controller and Adjustable Time Delay · 115v, 6 sec. – 20 min. · Surface-mounted       
    - J0039   Industrial Magnetic Reed Switch with Adjustable Time Delay · 115v, 1 sec. – 17 min. · Floor-mounted · NOTE: Control panel required     
    - J0040   Industrial Magnetic Reed Switch with Adjustable Time Delay, 1 sec. – 17 min. · Surface-mounted · NOTE: Control panel required           
    - J0042   Industrial Magnetic Reed Switch with Controller and Adjustable Time Delay · 208-230v 1Φ - 6 sec. – 20 min. · Surface-mounted    
     
    MOUNTING BRACKETS         
     
    Recommended for specific applications · Standard color Titanium Silver · NOTE: Units come standard with predrilled holes on back end for flush mounting      
     
    - J0016   5" Flat Side-Extension Plates - To clear track on either end · Set of 2          
    - J0017   7" Flat Side-Extension Plates - To clear track on either end · Set of 2          
    - J0018   9" Flat Side-Extension Plates - To clear track on either end · Set of 2          
    - J0004   2 1/2"-Clearance Adjustable-Angle Mounting Bracket - To clear wall obstructions · Set of 2        
    - J0005   4"-Clearance Adjustable-Angle Mounting Bracket - To clear wall obstructions · Set of 2   
    - J0006   7"-Clearance Adjustable-Angle Mounting Bracket - To clear wall obstructions · Set of 2   
    - J0007   10"-Clearance Adjustable-Angle Mounting Bracket - To clear wall obstructions · Set of 2 
    - J0008G  10"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket - For use over drum-style roll-up doors · Set of 2           
    - J0009G  16"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket - For use over drum-style roll-up doors · Set of 2           
    - J0010G  19"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket - For use over drum-style roll-up doors · Set of 2           
    - J0011G  23"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket - For use over drum-style roll-up doors · Set of 2           
     
    FILTERS
    - STD2-FILTER-[size]  STD2 Aluminum Mesh Filter 1/4’ Internal-mount · Set of 2 · [size]: Specify size in inches           
     
    MOTOR CONTROL PANELS
     
    Remote-mounted control panels for all 3Φ units and 1Φ units when greater than 1 hp (NEMA 1) · Units come standard with HOA (hand/off/auto) switch · Panel shipped loose · Standard color Battleship Gray · NOTE: Electric heated units include internal control panel and remote-mounted 24v thermostat with heat/off/fan only switch [vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60 U = 220/1/50     
     
    - MCPA-1U        1-Motor Control Panel ½ hp · Unheated
    - MCPA-2U        2-Motor Control Panel ½ hp · Unheated
    - MCPA-3U        3-Motor Control Panel 1⁄2 hp · Unheated
    - MCPA-4U        4-Motor Control Panel 1⁄2 hp · Unheated
    - MCPA-5U        5-Motor Control Panel 1⁄2 hp · Unheated
    - MCPA-6U        6-Motor Control Panel 1⁄2 hp · Unheated
    - MCPA-1V         1-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated
    - MCPA-2V         2-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated
    - MCPA-3V         3-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated
    - MCPA-4V         4-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated
    - MCPA-5V         5-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated  
    - MCPA-6V         6-Motor Control Panel 1⁄2 hp · Steam/ Hot Water Heated  
               
    PANEL ADD-ONS
     
    - 94-013  Adjustable Time Delay, 1 sec. - 17 min. · NOTE: Control panel required   
    - 99-165  Non-fused disconnect · 32 amps, Panel-mounted    
    - 99-164  Non-fused disconnect · 63 amps, Panel-mounted    
    - 99-114  Fused disconnect · 32 amps, Panel-mounted           
    - 99-115  Fused disconnect · 63 amps, Panel-mounted           
    - MCP-MTD  Factory-Mounted Motor Control Panel HL2SPD  2-Speed Motor with Switch Off/Lo/Hi · Panel-mounted switch · NOTE: if 460v power is specified, a separate 115v or 208-230 1Φ service is required  
    - MSLAV  Master/Slave Control with Single Thermostat
     
    MULTI-SPEED CONTROL OPTIONS  
     
    - 99-003  3-Speed Remote switch · 25 amps, Off/Lo/Med/Hi · Up to 1 hp 1Φ           
    - 99-033  2-Speed Remote Switch · 15 amps, Off/Lo/Hi · Up to 1 hp 1Φ        
    - 99-034  2-Speed Remote Switch · 25 amps, Off/Lo/Hi · Up to 1 hp 1Φ        

    RELATED APPLICATIONS

    • Heated Products Supplement .pdf
      576 KB
    • STD2.pdf
      12472 KB
    • Series 2 Trifold.pdf.pdf
      3506 KB
    • Plastic Strips vs Air Curtains .pdf
      546 KB
    • STD2 Unheated Submittals_5 .pdf
      848 KB
    • Accessory Installation Supplement.pdf
      2123 KB
    • Mars Corporate Brochure - CB001 July 2016 .pdf
      19290 KB
    • STD2 Electric Submittals_1.pdf
      664 KB
    • STD2 Hot Water-Steam Submittals_1.pdf
      699 KB
    • Mars Gate-Fold Brochure .pdf
      20994 KB
    Other
    Log in
    New to GM industry Sign up
    By signing up,you agree to our terms of use, privacy policy,and cookie policy
    have an account? Log in